Tracer-gas leak testing
 (

Rank: 100%
Bluestar Bluestar Bluestar Bluestar Blackstar

A tracer-gas leak testing method is a nondestructive testing method that detects . A variety of methods with different sensitivities exist. Tracer-gas leak testing is used in the petrochemical industry, the automotive industry, the construction industry and in the manufacture of , among other uses.


Types
Several tracer-gas leak testing methods exist, including:
  • Detection of leaks using helium mass spectrometer, which provides high sensitivity
  • Hydrogen leak testing, which provides the best mobility
  • Refrigerant gas leak detection, for refrigeration applications


Method selection

Typical leakage rates
The nature of the product or the process and the process gases will set the leak rate requirement:
Chemical process equipment10−1–1
Beverage can10−5 –10−6
Vacuum pumped system10−5–10−7
IC-package10−7–10−8
Airbag cartridge10−8
Pacemaker10−9
Closed vacuum system10−9


Sensitivity of methods
Based on the target leak rate, the table below will help to choose the most suitable method.
Ultrasonics−1>10−1
Bubble test in water10−2
Pressure decay10−2
Vacuum decay10−2
Acoustic emission detectors10−3
Bubble test in soapy water10−4
Gas-specific thermal conductivity detector10−5
Halogen detector10−5
Photoacoustic spectroscopy10−6
Hydrogen sniffer10−6
Residual gas analyser10−7
Dye penetrant10−8
Radioactive tracer10−10
Helium mass spectrometry vacuum testing10−11


Applications
Typical applications of tracer-gas leak testing include:
  • In petrochemical plants, hydrocracking, vapocracking, catalytic reforming, and are all -based processes, in which were hydrogen leak testing is required.
  • When manufacturing , all processes taking place in a process chamber at atmospheric pressure or under vacuum – diffusion, oxidation, , , PVD and – require helium or hydrogen leak testing.
  • In vehicles, have to be tested for leaks so they remain functional for a long time. As well as airbags, the air conditioning system, fuel system, and exhaust system require testing for leaks.
  • and have to be tested for efficacy and longevity.
  • On planes, tracer-gas leak testing is used to quickly and safely locate fuel leaks, as well as to check oxygen distribution devices and cabin pressurization systems.
  • Refrigeration and air conditioning must have the lowest possible rate of loss of gases (contributing to ).
  • Sewage and drinking water networks, to reduce loss of water and make sure drinking water is not contaminated by sewage.


Standards
Several standards apply to leak testing and more specifically to tracer-gas leak testing methods, for example:
  • BS EN 1779:1999; leak tightness by indication or measurement of gas leakage,
  • BS EN 13185:2001 Non-destructive testing. Leak testing. Tracer gas method,
  • BS EN 13192:2002 Non-destructive testing. Leak testing. Calibration of reference leaks for gases.